Strona główna
 
bezpieczniki.com > products > American general purpose fuses

American general purpose fuses
 

 

Type: AJT AMP-TRAP 2000R
Characteristic: low breaking capacity class J TD
Rated current: 1A-600A
Rated voltage: 600V AC and 500V DC
Rated breaking capacity: 600V AC - 200kA, 500V DC - 100kA
Standards: IEC 60269-2-1, UL/CSA 248.8, Rendition DC - UL 198L

 

Downloads
Catalog's pages PDF, 5 pages, 150 kB
 

 

Type: A4BQ (class L TD)
Characteristic: low breaking capacity
Rated current: 100-6000A for AC
and 100-3000A for DC
Voltage: 600V AC and DC
Rated breaking capacity: 200kA for AC and 100kA for DC

Sizes: 100-600A measurement: 51x219 mm
  601-800A   63x219 mm
  801-1200A   63x273 mm
  1201-1600A   76x273 mm
  1601-2000A   89x273 mm
  2001-2500A   114x273 mm
  2501-3000A   127x273 mm
  3001-4000A   146x273 mm
  4001-5000A   159x273 mm
  5001-6000A   181x273 mm

Standards: UL 248-10, CSA C22.2 no. 248.10, DC UL St. 198L

Downloads
Catalog's pages PDF, 4 pages, 140 kB
 

 

Type: A2D and A6D (class RK1 TD)
Characteristic: low breaking capacity
Rated current: 0,1A-600A
Voltage: 250 and 600 V AC
Max. breaking current: 200 (300) kA

Sizes:   250V   600 V
0-30A   14x51 mm   21x127 mm
31-60A   21x76 mm   27x139 mm
61-100A   27x149 mm   34x200 mm
101-200A   40x181 mm   46x244 mm
201-400A   53x219 mm   66x295 mm
401A-600A   66x264 mm   80x340 mm

Standards: UL 248-12, CSA 22.2 no. 248.12

Downloads
Catalog's pages PDF, 5 pages, 260 kB
 

 

Type: ATDR
Characteristic: low breaking capacity class CC TD
Rated current: 0,25A-30A
Rated voltage: 600V AC and 300V DC
Rated breaking capacity: 600V AC - 200kA, 300V DC - 100kA
Sizes: 10x38 (10,4x38,1 mm)
Standards: UL/CSA 248.4, Rendition DC - UL 198L

 

Downloads
Catalog's pages S PDF, 3 pages, 140 kB
 

 

Type: ATQR AMP-TRAP 2000R
Characteristic: low breaking capacity class CC TD
Rated current: 0,1A-30A
Rated voltage: 600V AC
Rated breaking capacity: 200kA
Sizes: 10x38 (10,4x38,1 mm)
Standards: UL/CSA 248.4

 

Downloads
Catalog's pages PDF, 4 pages, 140 kB
 

 

Fuses TRI-ONIC
Type: TR and TRS (class RK5 TD)
Characteristic: low breaking capacity
TR
AC: 0,1A-600A 250V AC, 200 kA
DC: 0,1A-2 0,8A and 35A-400A,
250 V DC, 20 kA,
3A-30A & 450A-600A,160VDC, 20kA
TRS
AC: 0,1A-600A, 600V AC, 200 kA
DC: 0,1A-12 A, 600V DC, 20 kA
70A-600A, 600V DC, 100 kA
15 - 60 A, 300 V DC, 20 kA
Standards: UL 248-12, CSA C22.2 no. 248.12, DC according to UL 198L

Sizes:   250V   600 V  
0-30A   14x51 mm   21x127 mm  
31-60A   21x76 mm   27x139 mm  
61-100A   27x149 mm   34x200 mm  
101-200A   40x181 mm   46x244 mm  
201-400A   53x219 mm   66x295 mm  
401A-600A   66x264 mm   80x340 mm  
Downloads
Catalog's pages PDF, 5 pages, 340 kB
 

 

Fuses TRI-ONIC
Type: TRS-RDC (DC according to TD)
Characteristic: low breaking capacity DC
Rated current:
1A-30A /300V DC
35A-400A /600V DC
Max. breaking current: 20 kA

Sizes: 0-30A   measurement: 21x127 mm  
  31-60A     27x139 mm  
  61-100A     34x200 mm  
  101-200A     46x244 mm  
  201-400A     66x295 mm  

Standards: MSHA no. 28-26-0

Downloads
Catalog's pages PDF, 2 pages, 85 kB
 

 

Fuses AMP-TRAP
Type: A4J (class J FA)
Characteristic: rapid
Rated current: 1A-600A
Voltage: 600V AC and 300V DC
Max. breaking current: AC 200 kA, DC 20 kA

Sizes: 1-30A   measurement: 21x57 mm  
  31-60A     27x60 mm  
  61-100A     29x117 mm  
  101-200A     41x146 mm  
  201-400A     54x181 mm  
  401A-600A     64x203 mm  

Standards: UL 248-8, CSA C22.2 no. 248.8, DC according to UL198L. EC 269-2-1

Downloads
Catalog's pages PDF, 3 pages, 128 kB
 

 

Fuses AMP-TRAP
Type: A4BY (class L)
Characteristic: low breaking capacity
Rated current:
200 - 6000 A /600V AC,
200 - 2500 A /300V DC,
Voltage: 600V AC and 300V DC
Max. breaking current: AC 200 kA, DC 100 kA

Sizes: 200-600A   measurement: 51x219 mm  
  601- 800A     63x219 mm  
  801-1200A     63x273 mm  
  1201-1600A     76x273 mm  
  1601- 2000A     89x273 mm  
  2001- 2500A     114x273 mm  
  2501- 3000A     127x273 mm  
  3001- 4000A     146x273 mm  
  4001- 5000A     159x273 mm  
  5001- 6000A     181x273 mm  

Standards: for applications of 601-6000A: UL 248-10, DC UL St. 198L, CSA C22.2 no. 248.10

Downloads
Catalog's pages PDF, 3 pages, 145 kB
 

 

Fuses AMP-TRAP
Type: A4BT (class L TD)
Characteristic: low breaking capacity
Rated current: 200A-2000 A
Voltage: 600V AC, 500V DC
Max. breaking current:
AC 200 kA, DC 100 kA

Sizes: 200-600A   measurement 51x219 mm  
  601- 800A     63x219 mm  
  801- 1200A     63x273 mm  
  1201-1600A     76x273 mm  
  1601- 2000A     89x273 mm  

Standards: for applications of 601-2000A: UL 248-10, DC UL St. 198L, CSA C22.2 no. 248.10
Applications: motors, transformers, panelboards, mains

Downloads
Catalog's pages PDF, 3 pages, 135 kB
 

 

Fuses AMP-TRAP
Type: A3T and A6T (class T FA)
Characteristic: rapid
A3T
1A-1200A 300V AC, 200 kA
1A-1200A 160V DC, 50 kA
A6T
1A-800A 600V AC, 200 kA
1A-800A 300V DC, 100 kA
Sizes: from 10,3x22,4 till 63,5x110 mm
Standards: UL 248-15, CSA C22.2 no. 248.15, DC UL St.198L

Downloads
Catalog's pages PDF, 5 pages, 200 kB
 

 

Fuses AMP-TRAP
Type: A2K and A6K (class RK1FA)
Characteristic: rapid
Rated current: 1A-600A
A2K: 250V AC and DC,
A6K: 600V AC and 300 V DC
Max. breaking current: 200 kA

Sizes:   250 V   600 V
0-30A   14x51 mm   21x127 mm
31-60A   21x76 mm   27x139 mm
61-100A   27x149 mm   34x200 mm
101-200A   40x181 mm   46x244 mm
201-400A   53x219 mm   66x295 mm
401A-600A   66x264 mm   80x340 mm

Standards: UL 248-12, CSA C22.2 no. 248.12, DC UL St. 198L

Downloads
Catalog's pages PDF, 5 pages, 180 kB
 

 

Fuses AMP-TRAP
Type: AG (class G)
Characteristic: low breaking capacity
Rated current: 0,5A-20A /600V AC
25-60A /480 V AC
Max. breaking current: 100 kA

Sizes: 0,5-15A   10,3x33,3 mm
  20A   10,3x35,8 mm
  25, 30A   10,3x41,2 mm
  35-60 A   10,3x57,2 mm

Standards: UL ST. 248-5, CSA C22.2 no. 248.5

Downloads
Catalog's pages PDF, 2 pages, 110 kB
 

 

Type: ATMR AMP-TRAP 2000R
Characteristic: low breaking capacity class CC TD
Rated current: 0,1A-30A
Rated voltage: 600V AC
Rated breaking capacity: 200kA
Sizes: 10,4x38,1 mm
Standards: UL/CSA 248.4
Applications: transformers from 50 till 1000VA, lighting, general loads

Downloads
Catalog's pages PDF, 2 pages, 185 kB
 

 

Fuses mocy One-Time
Type: OT, OTN, OTS (class K-5)
Rated current:
OT - 1A-600A 250V AC, 50 kA, 1A-600A 250V DC, 20 kA OTN (Canada) - 15A-60A, 250V AC, 50 kA OTS - 1A-600A 600V AC, 50 kA 1A-600A 300V DC, 20 kA

Sizes:   250V   600 V
0-30A   14x51 mm   21x127 mm
31-60A   21x76 mm   27x139 mm
61-100A   27x149 mm   34x200 mm
101-200A   40x181 mm   46x244 mm
201-400A   53x219 mm   66x295 mm
401A-600A   66x264 mm   80x340 mm

Standards: UL ST. 248-9, CSA C22.2 no. 248.9, DC according to UL198L,

Downloads
Catalog's pages PDF, 3 pages, 120 kB
 

 

Fuses mocy z wymiennym topikiem
Type: RF/RFS and RL/RLS (class H)
Rated current: 1A-600A
Voltage: RF - 250 V AC, RFS- 600 V AC
Max. breaking current: 10 kA
Sizes:
Standards: UL 248-7, CSA C22.2 no. 248.7

 

Downloads
Catalog's pages PDF, 1 pages, 110 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: ATQ 500 V AC (TD)
Characteristic: low breaking capacity
Rated current: 0,1A-30A
Voltage: 500 V AC
Max. breaking current: - 10 kA
Sizes: 10x38 mm
Standards: UL ST. 248-14, CSA C22.2 no. 248.14

 

Downloads
Catalog's pages PDF, 2 pages, 110 kB
 

 

Type: TRM Midget
Characteristic: low breaking capacity
Rated current: 0,1A-30A
Rated voltage: 250V AC
Rated breaking capacity: 10kA
Sizes: 10x38 mm
Standards: UL/CSA 248.4

 

Downloads
Catalog's pages PDF, 2 pages, 100 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: GFN
Characteristic: low breaking capacity
Rated current: 0,1A-30A
Parametry: 0,1A-10A 250V AC,
12A-15A, 125V AC
20A-30A, 32V AC
Max. breaking current: 200A for 250 V
for others 10 kA
Sizes: 10x38 mm

 

Downloads
Catalog's pages PDF, 1 pages, 75 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: A6Y-2B
Characteristic: rapid
Rated current: 0,25A-15A
Parametry: 0,25A-3A 600V AC, 3,2A-15A 500 V AC
Max. breaking current: 10 kA
Sizes: 10x38 mm

 

Downloads
Catalog's pages PDF, 1 pages, 75 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: ATM
Characteristic: rapid
Parametry: 0,1A-50A 600V AC, 0,1A-30A 500 V DC
Sizes: 10x38 mm
Standards: for 0,1A-30A - AC and DC: UL 248-14, CSA C22.2 no. 248.14

 

 

Downloads
Catalog's pages PDF, 1 pages, 80 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: OTM
Characteristic: rapid
Rated current: 1A-30A
Voltage: 250V AC
Max. breaking current: 10 kA
Sizes: 10x38 mm
Standards: UL 248-14, CSA C22.2 no. 248.14

 

Downloads
Catalog's pages PDF, 1 pages, 80 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: GGU
Characteristic: rapid
Rated current: 3A-30A
Voltage: 125V AC
Max. breaking current: 10 kA
Sizes: 10x38 mm
Applications: general purpose
Standards: 3 - 15 A: UL 248-14

Downloads
Catalog's pages PDF, 1 pages, 70 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: SBS
Characteristic: rapid
Rated current: 0,2A-30A
Voltage: 600V AC
Max. breaking current: 100 kA
Sizes: 10x35 mm
Standards: UL 248-14, CSA C22.2 no. 248.14 (according to UL 198G and CSA 59.2)

 

Downloads
Catalog's pages PDF, 1 pages, 150 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: PCF
Characteristic: rapid
Rated current: 1A-30A
Voltage: 600V AC and 500V DC
Max. breaking current: 100 kA
Sizes: 10x38 mm
Standards: UL

 

Downloads
Catalog's pages PDF, 1 pages, 75 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: PCS
Characteristic: very rapid
Rated current: 5A-30A
Voltage: 600V AC and DC
Max. breaking current: AC: 200 kA, DC: 100 kA
Sizes: 10x38 mm
Applications: to protect semiconductors
Standards: UL

Downloads
Catalog's pages PDF, 2 pages, 100 kB
 

 

Fuses Cylindrical (Special purpose fuses) Midget
Type: PCT
Characteristic: low breaking capacity
Rated current: 1A-30A
Voltage: 500V AC
Max. breaking current: 100 kA
Sizes: 10x38 mm
Standards: UL

Downloads
Catalog's pages